- Up to 1.25Gb/s dual data links
- Hot-pluggable SFP footprint
- 1310nm FP laser transmitter
- Duplex LC connector
- Up to 20km on 9/125um SMF
- Metal enclosure for lower EMI
- Single +3.3V power supply
- Low power dissipation <600mW
- Commercial operating temperature range: 0°C to +70°C
- 1.25Gb/s 1000Base-SX Ethernet
- 1.06 Gb/s Fibre Channel
Handar’s HD-S3112-20LCD Small Form Factor Pluggable (SFP) transceivers are compatible with the Small Form Factor Pluggable Multi-Sourcing Agreement (MSA). They simultaneously comply with Gigabit Ethernet as specified in IEEE STD 802.3 and 1x Fibre Channel as defined in FC-PI-2 Rev. 10.0 .They are RoHS compliant and lead-free.
I. Pin Descriptions
|
|
Pin
|
Symbol
|
Name/Description
|
Ref.
|
1
|
VeeT
|
Transmitter Ground (Common with Receiver Ground)
|
1
|
2
|
TX Fault
|
Transmitter Fault.
|
|
3
|
TX Disable
|
Transmitter Disable. Laser output disabled on high or open.
|
2
|
4
|
MOD_DEF(2)
|
Module Definition 2. Data line for Serial ID.
|
3
|
5
|
MOD_DEF(1)
|
Module Definition 1. Clock line for Serial ID.
|
3
|
6
|
MOD_DEF(0)
|
Module Definition 0. Grounded within the module.
|
3
|
7
|
Rate Select
|
No connection required
|
|
8
|
LOS
|
Loss of Signal indication. Logic 0 indicates normal operation.
|
4
|
9
|
VeeR
|
Receiver Ground (Common with Transmitter Ground)
|
1
|
10
|
VeeR
|
Receiver Ground (Common with Transmitter Ground)
|
1
|
11
|
VeeR
|
Receiver Ground (Common with Transmitter Ground)
|
1
|
12
|
RD-
|
Receiver Inverted DATA out. AC Coupled
|
|
13
|
RD+
|
Receiver Non-inverted DATA out. AC Coupled
|
|
14
|
VeeR
|
Receiver Ground (Common with Transmitter Ground)
|
1
|
15
|
VccR
|
Receiver Power Supply
|
|
16
|
VccT
|
Transmitter Power Supply
|
|
17
|
VeeT
|
Transmitter Ground (Common with Receiver Ground)
|
1
|
18
|
TD+
|
Transmitter Non-Inverted DATA in. AC Coupled.
|
|
19
|
TD-
|
Transmitter Inverted DATA in. AC Coupled.
|
|
20
|
VeeT
|
Transmitter Ground (Common with Receiver Ground)
|
1
|
Notes:
- Circuit ground is internally isolated from chassis ground.
- Laser output disabled on TX Disable >2.0V or open, enabled on TX Disable<0.8V.
- Should be pulled up with 4.7k - 10kohms on host board to a voltage between 2.0V and 3.6V.
MOD_DEF(0) pulls line low to indicate module is plugged in.
- LOS is LVTTL output. Should be pulled up with 4.7k – 10kohms on host board to a voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.
Pinout of Connector Block on Host Board
II. Absolute Maximum Ratings
|
|
Parameter
|
Symbol
|
Min
|
Typ
|
Max
|
Unit
|
Ref.
|
Maximum Supply Voltage
|
Vcc
|
-0.5
|
|
+4.0
|
V
|
|
Storage Temperature
|
TS
|
-40
|
|
+100
|
°C
|
|
Case Operating Temperature
|
TOP
|
0
|
|
+70
|
°C
|
|
Relative Humidity
|
RH
|
0
|
|
85
|
%
|
1
|
III. Electrical Characteristics (TOP=25°C, Vcc=3.3Volts)
|
|
Parameter
|
Symbol
|
Min
|
Typ
|
Max
|
Unit
|
Ref.
|
Supply Voltage
|
Vcc
|
3.00
|
|
3.60
|
V
|
|
Supply Current
|
Icc
|
|
160
|
300
|
mA
|
|
Transmitter
|
|
|
|
|
|
|
Input differential impedance
|
Rin
|
|
100
|
|
Ω
|
2
|
Single ended data input swing
|
Vin, pp
|
250
|
|
1200
|
mV
|
|
Transmit Disable Voltage
|
VD
|
Vcc – 1.3
|
|
Vcc
|
V
|
|
Transmit Enable Voltage
|
VEN
|
Vee
|
|
Vee+ 0.8
|
V
|
|
Transmit Disable Assert Time
|
|
|
|
10
|
us
|
|
Receiver
|
|
|
|
|
|
|
Single ended data output swing
|
Vout, pp
|
300
|
400
|
800
|
mV
|
3
|
Data output rise time
|
tr
|
|
|
300
|
ps
|
4
|
Data output fall time
|
tf
|
|
|
300
|
ps
|
4
|
LOS Fault
|
VLOS fault
|
Vcc – 0.5
|
|
VccHOST
|
V
|
5
|
LOS Normal
|
VLOS norm
|
Vee
|
|
Vee+0.5
|
V
|
5
|
Deterministic Jitter Contribution
|
RXΔDJ
|
|
|
80
|
ps
|
6
|
Total Jitter Contribution
|
RXΔTJ
|
|
|
122.4
|
ps
|
|
Notes:
- Non condensing.
- AC coupled.
- Into 100 ohm differential termination.
- 20 – 80 %
- LOS is LVTTL. Logic 0 indicates normal operation; logic 1 indicates no signal detected.
- Measured with DJ-free data input signal. In actual application, output DJ will be the sum of input DJ and ΔDJ.
IV. Optical Characteristics (TOP=25°C, Vcc=3.3 Volts)
|
|
Parameter
|
Symbol
|
Min
|
Typ
|
Max
|
Unit
|
Ref.
|
Transmitter
|
|
|
|
|
|
|
Output Opt. Power
|
PO
|
-15
|
-
|
-8
|
dBm
|
1
|
Optical Wavelength
|
λ
|
1275
|
1310
|
1350
|
nm
|
|
Spectral Width
|
σ
|
-
|
-
|
3
|
nm
|
|
Optical Rise/Fall Time
|
tr/tf
|
-
|
170
|
260
|
ps
|
2
|
Deterministic Jitter Contribution
|
TXΔDJ
|
-
|
-
|
0.07
|
UI
|
3
|
Total Jitter Contribution
|
TXΔTJ
|
-
|
-
|
0.007
|
UI
|
|
Optical Extinction Ratio
|
ER
|
9
|
-
|
-
|
dB
|
|
Receiver
|
|
|
|
|
|
|
Average Rx Sensitivity
|
RSENS
|
-
|
-
|
-24
|
dBm
|
4
|
Maximum Received Power
|
RXMAX
|
0
|
-
|
-
|
dBm
|
|
Optical Center Wavelength
|
λC
|
1270
|
-
|
1600
|
nm
|
|
LOS De-Assert
|
LOSD
|
-
|
-
|
-25
|
dBm
|
|
LOS Assert
|
LOSA
|
-36
|
-
|
-
|
dBm
|
|
LOS Hysteresis
|
|
0.5
|
-
|
-
|
dB
|
|
Notes:
- Class 1 Laser Safety, Tested with 50/125µm MM fiber.
- Unfiltered, 20-80%.
- Measured with DJ-free data input signal .In actual application, output DJ will be the sum of input DJ and ΔDJ.
- Measured with PRBS 27-1 at 10-12 BER .
V. General Specifications
|
|
Parameter
|
Symbol
|
Min
|
Typ
|
Max
|
Units
|
Ref.
|
Data Rate
|
BR
|
-
|
-
|
1250
|
Mb/sec
|
1
|
Bit Error Rate
|
BER
|
-
|
-
|
10-12
|
|
2
|
Max. Supported Link Length on
50/125μm MMF @ Gigabit Ethernet
|
LMAX
|
-
|
-
|
2
|
km
|
3,4
|
Notes:
- Gigabit Ethernet and 1x Fibre Channel compliant.
- Tested with a PRBS 27-1 data pattern.
- Dispersion limited per FC-PI-2 Rev. 10.
- Attenuation of 0.55 dB/km is used for the link length calculations. Please refer to the Optical Specifications in
Table IV to calculate a more accurate link budget based on specific conditions in your application.
VI. Environmental Specifications
|
HD 1310nm Commercial Temperature SFP transceivers have an operating temperature range from 0°C to +70°C case temperature.
Parameter
|
Symbol
|
Min
|
Typ
|
Max
|
Units
|
Ref.
|
Case Operating Temperature
|
Top
|
0
|
|
+70
|
°C
|
|
Storage Temperature
|
Tsto
|
-40
|
|
+100
|
°C
|
|